Spray is used to clean large fabricated equipment of Stainless steel e.g. Vessels equipment, internals & external surfaces of pipes by a pressurized spray bottle or pump.
AREA COVERED
Spray form covers 40-50 sq.ft. of an area with 1 kg. of the chemical.
APPLICATION PROCEDURE FOR SPRAY
Add 50 gms of SI. 56 Degreaser to 1 ltr. of water (5% w/v.). Apply solution on the surface for 10-15 minutes & then wash thoroughly and allow the surface to dry.
Spray is to be sprayed on the S.S. Surface with a pressurized plastic spray bottle or spray pump.
After spraying leave it for 30-60 minutes then scrub the surface with a plastic bristled brush.
Then wash the surface thoroughly with high-pressure water and allow the surface to dry.
Next, apply Passivation solution and leave it for 20-25 minutes.
Finally rinse the surface thoroughly with demineralized water and dry.
Note:
Chloride content in rinse water should be less than 50 ppm.
Shake the products well before use.
Do not apply the products under direct sunlight.
Passivation is a must after every pickling process.